发源地: | China |
品牌: | 仪表仪 |
Certification: | ISO,SGS |
型号: | DH-OA-150 |
Minimum Order Quantity: | 1套 |
---|---|
Price: | Negotiable |
包装细节: | 标准出口木箱 |
交货时间: | 大约7天 |
付款条件: | D/P, T/T, Western Union, MoneyGram |
供应能力: | 每月1000套 |
姓名: | 150L臭氧老化测试室20-98%的湿度范围 | 内部维度: | W500*H600*D500mm |
---|---|---|---|
Controller: | 7英寸,可编程,支持USB导出 | Temperature Range: | 5-100℃ |
湿度范围: | 20-98% | 重量: | 约220公斤 |
High Light: | 98% Humidity Ozone Aging Test Machine,,,,20%湿度臭氧老化测试机,,,,150L Ozone Aging Tester |
150L臭氧老化测试室20-98%湿度范围臭氧老化测试机
1. 150L(L代表升)
W500 x H600 x D500mm(w代表宽度,h表示高度,d表示深度) |
W1100 x H1700 x D1050mm(w代表宽度,h表示高度,d表示深度) |
约220公斤 |
AC220±5%v /50.5Hz |
应用
The content of ozone in the atmosphere is very small but it is the main factor of rubber cracking. This product simulates and strengthens the ozone conditions in the atmosphere, studies the law of the effect of ozone on rubber, and quickly identifies and evaluates the ozone resistance and aging resistance of rubber. The method of anti-ozonant protection efficiency. Reference standard: GB/T7762-2003 vulcanized rubber or thermoplastic rubber anti-ozone cracking static tensile test method, GB/T2951.21-2008 cable insulation and sheath material general test method, GB/T 11206-2009 Rubber aging test surface cracking method, and other test methods specified in related standards.
1.2。原理和方法
根据测试方法和标准,可以将测试方法分为“静态”和“动态”。静态意味着将样品拉伸并放置在测试框中进行测试,而动态表示样品放在测试框中。在固定装置上,在拉伸时进行测试,拉伸的波动约为测试样品本身的5%-45%
2. Main technical Parameters
2.1。温度范围:0℃-80℃
2.2。温度波动:±0.5℃温度分布精度:±2.0℃
2.3. Ozone concentration accuracy: 10~400pphm ±10%
2.4。升高样品架的频率:2R/min(可选)
2.5. Air velocity: 12~16mm/s
2.6。样品架速度:360度旋转样品架(旋转速度1〜3旋转每分钟或可选可调节)
3.结构特征
3.1. Structure: One machine.
a) 3.2. Material-inner box: SUS304 stainless steel plate
b)外盒:SUS304不锈钢板或烘焙清漆(米色白色)。
C)热绝缘:刚性聚氨酯泡沫 +铝硅酸盐热绝缘棉的双重保护。
a) 3.3. Box door-single open door, left open.
b) Two silicone rubber sealing strips for window frame/door frame and anti-condensation electric heating device.
c)观察窗口W300XH450mm和照明灯在门和窗户上配备了。
3.4. Requirements of the sample rack
a)(动态实验;可选)样品的两端,夹在所需的伸长率下。当与臭氧空气接触时,样品的长度应基本平行于气流方向
b)固定装置应由不容易分解臭氧的材料(例如铝)制成。
c)使样品旋转速度在(20^-25)mm/s之间,在垂直干燥空气平面中,每个样品沿着相同的路径连续移动
d) The time for one rotation of the same sample is (8^-12) min. The scanning area of the sample is at least 40% of the effective area of the test box.
e)应该满足从样品制备ents of GB/T 9865.1. The sample is best cut from the newly molded test piece, if necessary, it can be cut from the finished product. The sample should be at least 3 samples per test condition. The width of the long standard sample is not less than 10mm, the thickness is 2.0mm±0.2mm, and the length of the sample between the two ends of the clamp before stretching is not less than 40mm.
联络人:朱莉夫人
电话:86-13267004347
Fax:86-769-2318-1253
High Quality Hydraulic Pump Testing Machine , Universal Hydraulic Testing Machine 1000KN
皮革橡胶塑料的拉金宝搏188最新地址伸通用测试机 /强度测试机
WDW-2 Elongation Testing Machine / Single Column Wire Elongation Tester
数字塑料izod和charp pendulum撞击测试仪计算机控制
Computer Controlled HDT / Vicat Softening Point Apparatus Heat Distortion Testing Machine